Basic Specifications: |
Input | Pt100 platinum resistance sensor |
| Three lead with compensation or two lead sensor without compensation |
| Standard ranges | : -50 to +50°C, 0-50°C, 0-100°C, 0-200°C, 0-400°C, 0-600°C, 0-800°C |
| (others on request) |
| Sensing current | : 1.25mA dc |
Output | Load independent dc current |
| | : 4 to 20mA dc <750Ω load |
Accuracy | | : Class B to DIN 43760 ±(0.3 + 0.005t)°C, Class 0.5 |
| Range | : 0 - 100% |
Auxiliary Supply | | : Loop powered |
| | : 10 - 30Vdc injected into the loop |
Isolation | No galvanic isolation between input and output circuits |
| (Use LP-CDU, T-CDU or T-CDL to isolate) |
Temperature | Operating | : -10°C to +20°C to +50°C |
EMC Compliance | : AS/NZS 61000.6.3:2012 |